Calculates dissolved oxygen percent saturation from concentration.

DO_PerSat(Temp, DO, sal)

Arguments

Temp

temperature (Degree C)

DO

Dissolved oxygen (miligrams per liter)

sal

Salinity

Value

DO_PerSat() calculated dissolved oxygen percent saturation consistent with Florida Department of Environmental Protection technical support documents (https://floridadep.gov/sites/default/files/tsd-do-criteria-aquatic-life.pdf) using water temperature, dissolved oxygen concentration and salinity.

Examples

DO_PerSat(25.5,15.1,0); #Freshwater
#> [1] 184.4
DO_PerSat(25.5,15.1,33); #Marine
#> [1] 222.3